SOLAR INVERTER
This solar inverter supports a wide range of battery voltages, from 12V to 96V DC, with a minimum of 10.35V and a maximum of 132V. The nominal solar voltage ranges from 17V to 136V DC, with a minimum of 13V and a maximum of 184V. The solar charging current can range from 3A to 20A, while the inverter’s maximum continuous output power ranges from 600VA to 10.0KVA. The inverter features AC voltage regulation of 220/230V with 5% stability and frequency regulation of 50 Hz with 0.1% accuracy. The design features MOSFET/IGBT technology with a microcontroller, soft start, and fault protection. It has LED displays for system status and audible alarms for warnings. The inverter is suitable for operating temperatures between 0 to 50°C and is designed with FRP and sheet metal enclosures.
FOR BOOKING CALL US ON 080-23307412
| DESCRIPTION | SPECIFICATION |
| BATTERY VOLTAGE | 12/24/48/96 VDC NOMINAL |
| 10.35/20.7/41.4/82.8 VDC MINIMUM | |
| 16/33/66/132 VDC MAXIMUM | |
| SOLAR VOLTAGE | 17/34/68/136 VDC NOMINAL |
| 13/26/52/104 VDC MINIMUM | |
| 23/46/92/184 VDC MAXIMUM | |
| SOLAR CHARGING | |
| CURRENT | 3A – 20A |
| MAXIMUM INVERTER | |
| CONTINOUS O/P POWER | 600VA/800VA/1.5KVA/2.O KVA |
| 3.O KVA/5.0 KVA/7500VA/10.0KVA INVERTER MODE NOMINAL | |
| AC VOLT REGULATION | 220/230V SINGLE-PHASE SUITABILITY |
| 220/230 +/- 5% | |
| INVERTER MODE NOMINAL | |
| AC FREQUENCY REGULATION | 50 Hz+0.1% |
| WAVEFORM | SINUSOIDAL |
| DESIGN | MICROCONTROLLER, MOSFET /IGBT TECHNOLOGY |
| SOFT START | YES |
| INVERTER SURGE | |
| O/P RATING | 120% FOR 16 SEC |
| 150% FOR 1 SEC | |
| PEAK EFFICIENCY | >91% AT NOMINAL BATTERY VOLTAGE |
| AT 250C | |
| THD | <3% |
| OVERLOAD | AUTO RESET 4 OPERATIONS BEYOND SYSTEM SHUTDOWN, RESTART WITH RESET SWITCH |
| LED DISPLAY | INVERTER ON |
| BATTERY LOW | |
| SOLAR CHARGING ON | |
| MAINS CHARGING ON | |
| OVERLOAD | |
| FAULT PROTECTION | INVERTER OVERLOAD |
| O/P SHORT CIRCUIT | |
| BATTERY OVER VOLTAGE | |
| BATTERY UNDER VOLTAGE | |
| AUDIBLE ALARM | AT THE START, OVERLOAD, BATTERY LOW |
| OPERATING | |
| TEMPERATURE | 0 C TO 50 C |
| HUMIDITY | 5% to 95% NON-CONDENSING |