MICRO PROCESSOR BASED SERVO CONTROLLED VOLTAGE STABILIZER

Our stabilizers come in three different models: oil-cooled/3 phase, air-cooled/3 phase, and single phase, with a range of capacities from 1.0 KVA to 1000 KVA. These stabilizers are designed to manage unbalanced loads and inputs, with a nominal input range of 170V to 465V and an extended input range of 150V to 500V. With an efficiency of over 99% at full load and a speed of voltage correction of 70V/sec phase to phase, our stabilizers provide reliable and accurate voltage regulation. Additionally, our stabilizers come equipped with digital displays for all parameters, electronic overload and short circuit protections, and a manual bypass facility. They are built to standard IS 9815 and are encased in CRCA mild steel enclosures.

FOR BOOKING CALL US ON 080-23307412

 

DESCRIPTION OIL COOLED/3 phase AIR COOLED/3 phase SINGLE PHASE
MODEL
CAPACITY 50 KVA to1000 KVA 3.0 KVA to 100 KVA 1.0 KVA to 20.0 KVA
APPLICATION UNBALANCED LOAD & ONPUT UNBALANCED LOAD & ONPUT UNBALANCED LOAD & ONPUT
NORMINAL INPUT RANGE 330V to 465V 330V to 465 V 170V to 270 V
Extended input range 260V to 500V 260V to 500V 150V to 300V
OUTPUT VOLTAGE REGULATION #ERROR! #ERROR! #ERROR!
EIFFICIENCY >99% AT FULL LOAD >99% AT FULL LOAD >99% AT FULL LOAD
SPEED OF VOLTAGE CORRECTION 70 V/Sec PHASE to PHASE 70 V/Sec PHASE to PHASE 70 V/Sec
EFFECT OF LOAD POWER FACTOR Nil Nil Nil
DUTY CYCLE CONTINIOUS CONTINIOUS CONTINIOUS
SERVO MOTOR DRIVE AC SYNCHRONOUS AC SYNCHRONOUS AC SYNCHRONOUS
INDICATIONS DIGITAL DISPLAY FOR ALL PARAMETERS DIGITAL DISPLAY FOR ALL PARAMETERS DIGITAL DISPLAY FOR ALL PARAMETERS
METERING DIGITAL DISPLAY FOR ALL PARAMETERS DIGITAL DISPLAY FOR ALL PARAMETERS DIGITAL DISPLAY FOR ALL PARAMETERS
PROTECTIONS INPUT SHORT CIRCUIT
MCB / MCCB
SHORT CIRCUIT
MCB / MCCB
SHORT CIRCUIT/FUSE/MCB
PROTECTIONS OUTPUT ELECTRONIC OVER VOLTAGE TRIP
ELECTRONIC UNDER VOLTAGE TRIP
SINGLE PHASE PREVENTION
OVERLOAD & SHORT CIRCUIT
ELECTRONIC OVER VOLTAGE TRIP
ELECTRONIC UNDER VOLTAGE TRIP
SINGLE PHASE PREVENTION
OVERLOAD & SHORT CIRCUIT
ELECTRONIC OVER VOLTAGE TRIP
ELECTRONIC UNDER VOLTAGE TRIP
MANUAL BYPASS FACILITY THROUGH CHANGE OVER SWITCH THROUGH CHANGE OVER SWITCH THROUGH CHANGE OVER SWITCH
OPERATING TEMPP 0-50C 0-50C 0-50C
HUMIDITY 0-95%Rh NON CONDENSING 0-95%Rh NON CONDENSING 0-95%Rh NON CONDENSING
ENCLOSURE CRCA MID STEEL CRCA MID STEEL CRCA MID STEEL
STANDARD FOR STABILIZER As per IS 9815 As per IS 9815 As per IS 9815
STANDARD FOR OIL As per IS 335