15.0 KVA ONLINE UPS 3 PHASE INPUT AND 1 PHASE OUTPUT
The AC input of this device operates on 415V +/- 20% three-phase four-wire voltage and 50Hz +/- 10% frequency. The digital display shows DC voltage, AC voltage, frequency, output voltage, and connected load. Audio alarms warn of battery low, overload, overvoltage, and under voltage. The device uses APWN technology with IGBT and has forced air cooling. It supports lead-acid, tubular, and SMF battery types, with a battery voltage of 240 V. The AC output voltage is 230V+/-2% Single Phase, and the frequency is 50Hz +/-0.5Hz, with pure sine wave waveform and better than 98% efficiency. It has various protections against battery low, short circuit, overload trip, mains cut off, phase failure, and abnormal phase sequence. The device is suitable for computers, hospitals, CNC machines, and all types of industrial applications. Optional features include manual/static bypass, power factor correction, remote display/control, software, and SNMP compatibility.
| AC INPUT | |
| VOLTAGE |
415V +/- 20% Three Phase Four Wires
|
| FREQUENCY | 50Hz +/- 10% |
| DIGITAL DISPLAY |
DC VOLTAGE, AC VOLTAGE, FREQUENCY, OUTPUT VOLTAGE & CONNECTED LOAD
|
| AUDIO ALARMS | |
| BATTERY LOW, OVER LOAD, OVER VOLTAGE, UNDER VOLTAGE | |
| TECHNOLOGY | APWN TECHNOLOGY WITH IGBT |
| COOLING | FORCED AIR COOLING |
| BATTERY TYPE | LEAD ACID, TUBULAR, SMF |
| BATTERY VOLTAGE | 240 V |
| AC OUTPUT | |
| VOLTAGE | 230V+/-2% Single Phase |
| FREQUENCY | 50Hz +/-0.5Hz |
| WAVE FORM | PURE SINE WAVE |
| TRANSFER TIME | NIL |
| EFFICIENCY | BETTER THAN 98% |
| TRANSIENT VOLTAGE VARIATION | +/- 2%MAX |
| POWER FACTOR | 0.80 LAGGING |
| OVER LOAD | 125% FOR 10 MIN & 150% FOR 1 MIN |
| STATIC VOLTAGE REGULATION | 6% for 50% STEP LOAD CHARGE |
| DYNAMIC VOLTAGE REGULATION |
1%of NORMINAL FOR ALL VARIATIONS OF LINE LOAD 10% to 100% STEP LOAD CHANGE.
|
| WAVE FORM | SINUSOIDAL |
| TOTAL HARMONIC DISTORTION |
FOR LINEAR LOADS 2.5% FOR NON LINEAR LOADS 5%
|
| CREST FACTOR | 1:3 |
| OPERATING TEMPERATURE | |
| RANGE | 0 C to 40 C |
| RELATIVE HUMIDITY | 95% NON CONDENSING |
| Max. OPERATING ALTITUDE | |
| WITHOUT DERATING | 7500ft / 2285m |
| ACOUSTIC NOISE | <60 db |
| OPTIONAL |
MANUAL/STATIC BY PASS PF CORRECTION/REMOTE DISPLAY/CONTROL SOFTWARE/SNMP COMPATIBILITY
|
| PROTECTION |
BATTERY LOW, SHORT CURCUIT, OVERLOAD TRIP, MAINS CUT OFF, PHASE FALIURE, ABNORMAL PHASE SEQUENCE.
|
| APPLICATION |
COMPUTERS, HOSPITALS, CNC MACHINES AND ALL TYPES OF INDUSTRIAL APPLICATION.
|